Reasons for insufficient flow rate of melt pump
Our company's new melt pump capacity is insufficient at the speed of 38r/rain, the actual output is only 78t/d, while the normal output should be 93t/d, so the machine is shut down again for emergency repair. The pump head was boiled at high temperature with langenol. It is found that the total axial clearance between the gear and the bearing is about 1.3 mm. The same type of pump head (assembled and repaired by Beijing Bamag Technical Service Department) in a slice factory is checked comparatively.
The corresponding clearance is 0.18 nun (active) and 0.22 nun (driven). Check other aspects and find any problems. Obviously, excessive axial clearance causes the pump head to have an inner mattress. It is the main reason that the capacity of melt pump is seriously insufficient.